EasyManua.ls Logo

Epson StylusPro 10000 - Print; Shutter

Epson StylusPro 10000
323 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
73
5.3.8.9 Print
Perform the print reliability test.
Perform the pattern print designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the print reliability test menu sequence.
Figure 5-106.
o
The maximum value of the reliability number designation is [99,999,999 times].
5.3.8.10 Shutter
Perform the shutter reliability test.
Perform the shutter actuation designated number.
When the reliability number is [-1], reliability is repeated until [Pause] key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the shutter reliability test menu sequence.
Figure 5-107.
o
Where the shutter is transited ("closing condition"-> "Half open condition" ->
"Full open condition"), the reliability number is counted up of 1 time.
o The maximum value of the reliability number designation is [99,999,999 times].
Enter
End : 50
Count:10
Cut : on
Clear Print Cnt?
Print Number :
Adjustable with "Paper Feed +/-" key.
Change the ON/ OFF with "Paper
Feed +/-" key.
Clear with "Enter" key.
Cancel with "Pause" key.
Enter
Enter
Enter
End : 50
LifeCount:-1
Count:10

Table of Contents