EQUIPMENT
(1) Opto-coupler output can be connected to DINLINE Alarm Relay (DAR275V) to provide Form C dry contacts.
*STATUS SENSE
*
WARNING
ERICO products shall be installed and used only as indicated in ERICO’s product instruction sheets and training materials. Instruction sheets are
available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure
to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death.
Copyright ©2008 ERICO International Corporation. All rights reserved.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation.
www.erico.com
ANSI is a registered trademark of the American National Standards Institute. IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers,
Incorporated. NEMA is a registered trademark of the National Electrical Manufacturers Association. UL is a registered trademark of Underwriters Laboratories, Inc.
Features
The TDF series has been specifi cally designed
for process control applications to protect the
switched mode power supply units on devices
such as PLC controllers, SCADA systems and
motor controllers. Units are UL
®
Recognized
and available for 3A, 10A and 20A loads and
suitable for 110-120V ac/dc and 220-240Vac
circuits.
The TDF is a series connected, single phase
surge fi lter providing an aggregate surge
capacity of 50kA (8/20μs) across L-N, L-PE,
and N-PE. The low pass fi lter provides up to
65dB of attenuation to voltage transients.
Not only does this reduce the residual
let-through voltage, but it also helps
further reduce the steep voltage rate-of-rise
providing superior protection for sensitive
electronic equipment.
CRITEC
®
Transient
Discriminating
(TD) Technology
provides increased
service life
In-line series
protection
High effi ciency
low pass sine wave
ltering – ideal
for the protection
of switched mode
power supplies
Three modes of
protection: L-N,
L-PE & N-PE
35 mm DIN rail
mount – simple
installation
LED status
indication and
opto-isolated
output – for
remote status
monitoring
CE, UL
®
1449
Ed. 3 Listed
CRITEC
®
Transient Discriminating Filter
TDF
LINE
Model TDF3A120V TDF3A240V TDF10A120V TDF10A240V TDF20A120V TDF20A240V
Item Number for Europe 700001 700002 700003 700004 700005 700006
Nominal Voltage, U
n
110-120 V 220-240 V 110-120 V 220-240 V 110-120 V 220-240 V
Distribution System TN-C-S, TN-S
Max Cont. Operating
Voltage, Uc
170VAC 340VAC 170VAC 340VAC 170VAC 340VAC
Stand-off Voltage 240V 400V 240V 400V 240V 400V
Frequency 0-60Hz 50/60Hz 0-60Hz 50/60Hz
Max Line Current, I
L
3 A 10 A 20 A
Operating Current @ U
n
135 mA 250 mA 240 mA 480 mA 240 mA 480 mA
Max Discharge Current,
I
max
10kA 8/20μs N-PE
20kA 8/20μs L-N
20kA 8/20μs L-PE
Protection Modes All modes protected
Technology In-line series low pass sine wave fi lter
TD Technology
Voltage Protection Level,
U
p
500V @ 500A
250V @ 3kA
700V @ 500A
600V @ 3kA
500V @ 500A
250V @ 3kA
700V @ 500A
600V @ 3kA
500V @ 500A
250V @ 3kA
700V @ 500A
600V @ 3kA
Filtering -62dB @ 100kHz -65dB @ 100kHz -53dB @ 100kHz
Status Green LED. On=Ok. Isolated opto-coupler output
Dimensions H x D x W:
mm (in)
90 x 68 x 72
(3.54 x 2.68 x 2.83)
90 x 68 x 144
(3.54 x 2.68 x 5.67)
Module Width 4 M 8 M
Weight: kg (lbs) 0.7 (1.54) 1.48 (3.25) 1.57 (3.46)
Enclosure DIN 43 880, UL94V-0 thermoplastic, IP 20 (NEMA
®
-1)
Connection 1 mm² to 6 mm² (#18AWG to #10)
Mounting 35 mm top hat DIN rail
Back-up Overcurrent
Protection
3A 10A 20A
Temperature -35°C to 55°C (-31°F to 131°F)
Humidity 0% to 90%
Approvals C-Tick, CE (NOM 3A, 120V), CSA 22.2, UL
®
1283,
UL
®
1449 Ed 3 Recognized Component Type 2
Surge Rated to Meet ANSI
®
/IEEE
®
C62.41.2 Cat A, Cat B, Cat C
Vendor Manual Surge Filter Alarm Relay Critec TDF-10A-240V
Q-Pulse Id: VM90
08/02/2013
Page 1 of 4
Question and Answer IconNeed help?

Do you have a question about the ERICO TDF-3A-120V and is the answer not in the manual?

Summary

Installation Instructions

Preparation and Safety Precautions

Essential steps and safety warnings before installing the surge protector.

Product Introduction

Overview of Transient Discriminating Filters (TDF) and their packaging.

Quick Installation Steps

A concise overview of the steps required for installing the TDF module.

Protection Concepts and Wiring Separation

Explains optimal TDF protection through wiring separation principles.

Mounting Instructions

Details on how to mount the TDF module onto a 35mm DIN rail.

GFCI Considerations

Guidance on installing TDF modules prior to Ground Fault Circuit Interrupters.

Conductor Termination

Specifications for connecting conductors to TDF terminals.

Fusing and Isolation Requirements

Information on upstream overcurrent protection for TDF units.

Status Indication

Explanation of the TDF's status indicator and its meaning.

Maintenance and Testing

Procedures for maintaining and testing TDF modules.

Dinline Alarm Relay (DAR)

Details on using the DAR module for TDF status monitoring.

Use of Other Interfaces

Guidelines for interfacing with the TDF opto-coupler alarm output.

Overview

The ERICO CRITEC® Transient Discriminating Filter (TDF) is a series-connected, single-phase surge filter designed for process control applications. It specifically protects switched-mode power supply units in devices such as PLC controllers, SCADA systems, and motor controllers. The TDF series is available for 3A, 10A, and 20A loads and is suitable for 110-120V AC/DC and 220-240V AC circuits.

Function Description:

The TDF utilizes CRITEC® Transient Discriminating (TD) Technology, which enhances service life. It provides in-line series protection and features high-efficiency low-pass sine wave filtering, making it ideal for protecting switched-mode power supplies. The filter offers three modes of protection: Line-to-Neutral (L-N), Line-to-Protective Earth (L-PE), and Neutral-to-Protective Earth (N-PE). It provides an aggregate surge capacity of 50kA (8/20µs) across L-N, L-PE, and N-PE. The low-pass filter delivers up to 65dB of attenuation to voltage transients, reducing residual let-through voltage and the steep voltage rate-of-rise for superior protection of sensitive electronic equipment.

Important Technical Specifications:

  • Nominal Voltage (Un): 110-120 V or 220-240 V. The 120Vac unit also operates on nominal 125Vdc supplies.
  • Distribution System: TN-C-S, TN-S.
  • Max Continuous Operating Voltage (Uc): 170VAC (for 110-120V nominal) or 340VAC (for 220-240V nominal).
  • Stand-off Voltage: 240V (for 110-120V nominal) or 400V (for 220-240V nominal).
  • Frequency: 0-60Hz or 50/60Hz.
  • Max Line Current (IL): 3A, 10A, or 20A.
  • Operating Current @ Un: 135 mA (3A model), 240 mA (10A model), 240 mA (20A model for 220-240V), or 480 mA (20A model for 110-120V).
  • Max Discharge Current (Imax): 20kA 8/20µs L-N, 20kA 8/20µs L-PE, 10kA 8/20µs N-PE.
  • Voltage Protection Level (Up):
    • For 110-120V models: 500V @ 500A, 250V @ 3kA.
    • For 220-240V models: 700V @ 500A, 600V @ 3kA.
  • Filtering: -62dB @ 100kHz (3A model), -65dB @ 100kHz (10A model), -53dB @ 100kHz (20A model).
  • Dimensions (H x D x W):
    • 3A models: 90 x 68 x 72 mm (3.54 x 2.68 x 2.83 in).
    • 10A and 20A models: 90 x 68 x 144 mm (3.54 x 2.68 x 5.67 in).
  • Module Width: 4 M (3A model), 8 M (10A and 20A models).
  • Weight: 0.7 kg (1.54 lbs) for 3A, 1.48 kg (3.25 lbs) for 10A, 1.57 kg (3.46 lbs) for 20A.
  • Enclosure: DIN 43 880, UL94V-0 thermoplastic, IP 20 (NEMA®-1).
  • Connection: 1 mm² to 6 mm² (#18AWG to #10).
  • Mounting: 35 mm top hat DIN rail.
  • Back-up Overcurrent Protection: 3A, 10A, or 20A, depending on the model.
  • Temperature Range: -35°C to 55°C (-31°F to 131°F).
  • Humidity: 0% to 90%.
  • Approvals: C-Tick, CE (NOM 3A, 120V), CSA 22.2, UL® 1283, UL® 1449 Ed 3 Recognized Component Type 2.
  • Surge Rated to Meet: ANSI/IEEE® C62.41.2 Cat A, Cat B, Cat C.

Usage Features:

  • DIN Rail Mount: Designed for simple installation onto 35 mm DIN rails (standard EN50022).
  • Status Indication: Features a green LED on the front panel. When power is applied and full surge capacity is available, the LED illuminates. If the LED fails to illuminate, the TDF should be replaced.
  • Remote Status Monitoring: Includes an isolated opto-coupler output for remote status monitoring. This output can be connected to a DINLINE Alarm Relay (DAR275V) to provide Form C dry contacts.
  • Wiring: Terminals accept wire sizes from 10 to 18 AWG (1.5mm² to 6mm²) solid or stranded conductor. Wire insulation should be stripped back 5/16" (8mm).
  • Overcurrent Protection: Upstream overcurrent protection (breaker or fuse) is required for every TDF to protect the unit, load, and wiring. Max fuse sizes are 4A for 3A TDF, 10A for 10A TDF, and 20A for 20A TDF.
  • Wiring Separation: For optimal effectiveness, unprotected wiring (from the exposed transient source to the TDF) should be separated from protected wiring (on the equipment side of the TDF) by approximately 12" (300mm) to minimize cross-coupling.
  • Reverse Connection: For applications where the transient source is on the load side, the TDF can be reverse connected with the INPUT/LINE terminals connected to the load side.

Maintenance Features:

  • Inspection: TDF units should be inspected periodically, and after any periods of lightning or transient voltage activity.
  • Replacement: If the Status Indicator LED fails to illuminate, the TDF module should be replaced by qualified personnel.
  • Safety: Ensure power is removed from the area and circuits before installation or maintenance. Do not perform a "Flash Test" or use a Mega-Ohm Meter (Megger) on protected circuits, as this may damage the TDF modules.
  • Warranty: Do not open or tamper with the TDF units, as this may compromise performance and void the warranty.

ERICO TDF-3A-120V Specifications

General IconGeneral
BrandERICO
ModelTDF-3A-120V
CategoryWater Filtration Systems
LanguageEnglish