EasyManua.ls Logo

Ericsson ASB 150 02 - Flow Chart: Digital Trunk Does Not Work At All

Ericsson ASB 150 02
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19(42)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
1999-07-15 F
1545-ASB 150 02 Uen
FAULT TRACING DESCRIPTION
Faktaansvarig - Subject responsible
2.6 Flow chart: Digital trunk does not work at all
Correct programming
Is the
Y
Check in RASC the link
supervision if synchroni-
sation is possible.
Warnings
Y
logged for the
card functions?
Did this
Y
board work before?
Connect to RASC.
firmware?
Is the
hardware setup
ok? Correct jumper
settings and/or
Y
Correct hard-
ware setups
N
N
Did this
Y
board work before?
Swap board.
Y
Does it function
correctly?
Send to swap repair
with fault report
network/line
signalling selection
link correct?
N
Is the
Y
ISDN termi-
nation selection
correct?
N
Change selection
Are the
Y
services used
in the PBX subscri-
bed correctly?
N
Change termination
Are the
Y
services used
in the PBX subscri-
bed correctly?
N
If possible collect the signalling
trace and forward it with the
fault report. (see point 4.13)
AA
AA
= Go to " Completion of service" on page 31
AE
From
page 12
1
1
N
N
N

Table of Contents