Front Panel Control
4-24
EN/LZT 790 0023/1 R16A
IP Redundancy Mode
Active-Active, Active-Standby. Describes how the spare interfaces will
behave. For the Input data interface group only Active-Active is
supported and is a read only parameter. For the Output data
interface group both options are available.
Index Identifier of the interface group. Read only parameter.
Autorevert
Auto-revert to Primary, Auto-revert to Secondary. Shown only if the IP
Redundancy mode is set to Active-Standby. Determines what to do
when connection is lost.
Autorevert Delay
The delay in seconds before automatic redundancy switching takes
place. Shown only if the IP Redundancy mode is set to Active-
Standby.
Active Interface
Read only parameter. Displays which interface is active. In Active -
Active redundancy mode both interfaces are active.
Line Speed Auto, 100 Mpbs, 1 Gbps. The transmission speed of the link.
Duplex Mode
Auto, Full Duplex, Half Duplex. Determines whether data should be
transmitted and received in a time divided manner (Half Duplex) or
transmission and reception can happen at the same time over the
same link (Full Duplex). Auto is for automatic configuration.
Default Virtual MAC Address Virtual MAC address assigned to the current Data Interface Group.
IP Address The IP address associated with the interface group.
Subnet Mask The subnet mask associated with the interface group.
Gateway Address The gateway address associated with the interface group.
Physical Data Interface <m>
The physical data interface labelled as Ge <m> of the current data
interface group.
Port Type Ethernet. Read only parameter.
Direction Output. Read only parameter.
Index Identifier of the physical data interface. Read only parameter.
Default MAC Address The hardware address of the Ge <n> interface.
Link Status
Link Down, Link Up. The status of the current physical data interface.
Read only parameter.
Link Up Time
The time in days, hours, minutes and seconds the link is established.
Read only parameter.
TX Packets Packets transmitted since the link is up. Read only parameter.
RX Packets Packets received since the link is up. Read only parameter.
IP Address The IP address of the physical data interface.
Use Data Interface Group 3_4
If true data Ethernet ports Ge 3 and Ge 4 are used for control network
access to the unit.
If false the Ethernet control ports are used for control network access
to the unit.
Note: Changing this value will automatically reboot the unit.
Model
Unit Name The name of the current unit for displaying on the web user interface.