5.3.2 Using the Stored Configuration Page
This section describes the tasks that can be completed on the Stored Configuration
Page.
5.3.2.1 Storing the Current Configuration
The unit provides 64 configuration slots for storing different configurations. On
delivery, all store locations are empty. When the user has configured the unit with a
complete set of parameters the configuration can be saved to a store location.
Configurations can be saved at any time. To save the current configuration, do the
following:
1. In the Stored Configurations widget, select the slot you want to use for storing
the configuration. If the slot is not empty, it will be overwritten.
2. In the Name field in the Configuration Workbench widget, enter a name for the
configuration.
3. You can also add a description in the Description field if you wish. The
description can help identifying the configuration in the future.
4. Click on the Save Config button within the Configuration Workbench widget.
5. A confirmation dialog will appear. Choose Yes to save the configuration in the
selected slot.
Once stored the configuration is available to be recalled and used at any time. The
table below describes each main action associated with the stored configurations.
Table 5.2 Stored Configuration Parameters
Parameter Description
Restore
Restores the configuration from the selected stored onto the unit. Select required stored number and press
Restore
Save Config
Saves the current unit configuration into the selected store location. Select required store number, enter Name
and Description and press Save Config
Edit
Allows Store Name and Description to be changed. Select required store, modify the Name and/or Description as
required and press Edit to save the modified text only. The stored configuration data will not be affected
Delete Delete contents, name and description of selected store. Select required store number and press Delete
Import
Imports a configuration from file to selected store location. Browse to required file and select Import. This does
not affect unit configuration.
The file being imported must be in the same format (ie exported from the stored configurations function rather
than the save-load XML
Export
To export the selected configuration to a file, move the mouse pointer over the link, right click and select Save
target as... or Save link as..., dependent on the browser you are using. You will then be prompted for a filename
and a place to store the file. Give the file a .xml extension.
Update Properties Refreshes the contents of the list and the workbench from the unit.