The unit provides 64 configuration slots for storing different configurations.
Configurations can be restored at any time. To restore a previously stored
configuration, do the following:
1. In the Stored Configurations widget, select the configuration you want to
restore.
2. The Configuration Workbench widget will display the properties of the selected
stored configuration.
3. To restore the configuration, click the Restore button in the Configuration
Workbench widget.
5.3.2.3 Exporting a Configuration
The unit provides 64 configuration slots for storing different configurations. The
content of any of the slots can be exported. Exported configurations from a previous
version of the unit can be fed to the Configuration Converter Tool and converted
to the current version. To export a previously stored configuration, do the following:
1. In the Stored Configurations widget, select the configuration you want to
restore.
2. The Configuration Workbench widget will display the properties of the selected
stored configuration.
3. To export the configuration, click the Export button in the Configuration
Workbench widget.
4. In the popup window, select the Save file option.
5. By default, the file will be saved in the Downloads folder on your computer.
Note: The format of files exported from a Stored Configurations page is not
compatible with the files saved on the General tab of the Support page.
Similarly files saved on the Support page cannot be imported into stored
configurations.
5.3.2.4 Importing a Configuration
The unit provides 64 configuration slots for storing different configurations. The
content of any of the slots can be exported. Exported configurations from a previous
version of the unit can be fed to the Configuration Converter Tool and converted
to the current version. To import a converted configuration, do the following:
1. In the Stored Configurations widget, select the slot you want to use to store
the imported configuration.
2. Click on the Browse button within the Configuration Workbench widget.
3. In the popup window, browse to the file you want to import, and click Open.
4. The file name will be populated into the text box next to the Browse button.