Web GUI Control
5-118
EN/LZT 790 0023/1 R16A
Video Output
The following parameters are available on the Output tab of the Properties widget on the
Service Configuration page when a video component is selected in the Outputs widget.
The same parameters can be accessed through the Advanced/Video/Video 1/Video/Main
Video/Stream Output menu on the front panel.
Table 5.94 Video Output Parameters
Parameter Values Description
Embedded PCR Off, On
Sets if the PCR is embedded within the video. If it is set to
other than Off, the PCR PID field of a service will become
read only and will contain the PID of the current
component.
Copyright Off, On Sets the copyright flag in the elementary stream header.
Original Off, On Sets the original flag in the elementary stream header.
AR Signalling Output
Control
Off, AFD Only, AFD and Bar Data
Controls which source is used for embedding aspect ratio
signalling into user data. If set to Off, no aspect ratio data
will be resent in the output. AFD sources are: SMPTE
2016, Video Index, WSS-AFD/WSS, user set Aspect
Ratio. Bar Data is only SMPTE 2016.
TC Output Location Off, SEI Message Defines how timecode is put into the output video stream.
Closed Captions Off, ATSC (default)
Controls if Closed Captions are included in the output
stream
Video Component
The following parameters are available on the Component tab of the Properties
widget on the Service Configuration page when a video component is selected in
the Outputs widget. The same parameters can be accessed through the
Output/<output name>/Transport Stream ID: <n>/Service List/<service
name>/Component List/Slot <x> Video Stream on PID <y> menu on the front
panel.
Table 5.95 Video Component Parameters
Parameter Values Description
PID 16 to 8190 Sets the packet identifier associated with the component.
Bit Rate Weighting Fixed, Minimum, 2 to 20
Specifies the weight associated to the component in the
Bit Rate Tracking algorithm.
Master TS Off, On Sets the master Transport Stream for the component.
Source PID Monitoring None, Monitor, Monitor & Redundancy
Priority 1 ETR290 monitoring on this PID from an IP input
can be enabled, and can be set to cause a redundancy
switch to a spare device if in a system controlled by
Ericsson control software. Not supported in this release.
Vertical Blanking Interval / Ancillary Data
The following parameters are available on the VBI tab of the Properties widget on
the Service Configuration page when a video stream is selected in the Outputs
widget. The same parameters can be accessed through the Advanced/CE-
HEVC/Video/Video 1/Input/VBI Extraction menu on the front panel.

Table of Contents