Getting Started
must be set to ON (either reduced or nominal power) and the modulation state
must also be ON. These parameters are also available in the Device
Configuration menus.
16. The status of the modulator output is indicated by the icons in the banner at the
top of the user interface.
Note: All Transport Streams can be set online in one go by selecting all of them
and clicking on the Online button.
3.8.4 How to Configure the PCR
By default, the unit will use a PCR embedded in the video. If a separate PCR is
required the following steps are necessary:
1. Turn off embedded PCR in the Video Component Output Properties panel.
Figure 3.8 Video Component Output
2. Select the Video PCR Stream from the video input list and drag and drop it into
the output service.
3. Configure the required PCR PID on this component.
4. Select Outputs >Service – n and set the PCR PID to the same value as that set
for the component.