Front Panel Control
EN/LZT 790 0023/1 R16A
4-23
unit with the same IP address within the network by sending out ARP
messages.
Control Interface Group
Network Mode
Same-Network, Different-Network. Read only parameter for the
control interface, and is set to Same-Network.
IP Redundancy Mode
Active-Active, Active-Standby. Describes how the spare interfaces will
behave. For the control port, it is set to Active-Standby and is read
only.
Index Identifier of the interface group. Read only parameter.
Autorevert
Auto-revert to Primary, Auto-revert to Secondary. Shown only if the IP
Redundancy mode is set to Active-Standby. Determines what to do
when connection is lost.
Autorevert Delay
The delay in seconds before automatic redundancy switching takes
place. Shown only if the IP Redundancy mode is set to Active-
Standby.
Active Interface
Read only parameter. Displays which interface is active. In Active -
Active redundancy mode both interfaces are active.
Line Speed Auto, 100 Mbps, 1 Gbps. The transmission speed of the link.
Duplex Mode
Auto, Full Duplex, Half Duplex. Determines whether data should be
transmitted and received in a time divided manner (Half Duplex) or
transmission and reception can happen at the same time over the
same link (Full Duplex). Auto is for automatic configuration.
Default MAC Address Virtual MAC address assigned to the Control Interface Group.
IP Address The IP address associated with the interface group.
Subnet Mask The subnet mask associated with the interface group.
Gateway Address The gateway address associated with the interface group.
Physical Control Interface <n>
The physical data interface labelled as Ge <n> of the current control
interface group.
Port Type Ethernet. Read only parameter.
Direction Output. Read only parameter.
Index Identifier of the physical data interface. Read only parameter.
Default MAC Address The hardware address of the Ge <n> interface.
Link Status Link Down, Link Up. The status of the current physical data interface.
Link Up Time
The time in days, hours, minutes and seconds the link is established.
Read only parameter.
TX Packets The packets transmitted since the link is up.
RX Packets The packets received since the link is up.
IP Address The IP address of the physical data interface.