Web GUI Control
Parameter Values Description
Field 2
VBI Line 272 - VBI
Line 285
Off, Closed Caption
Specifies the content in the respective VBI lines. Set to
Off if the line in the incoming video does not carry any
information, Closed Caption for closed caption
information. Visible for 480i (525-line) input streams.
VBI Line 319 - VBI
Line 336
Off, VITC, WSS, WSS-AFD, Teletext System B
Specifies the content in the respective VBI lines. Set to
Off if the line in the incoming video does not carry any
information, VITC for Time Code, WSS for Wide Screen
Signaling, WSS-AFD for Active Format Detection and
Teletext System B for Teletext.
ANC Component
This section describes the parameters associated with the component carrying
ancillary data.
The following parameters are available on the Component tab of the Properties
widget on the Service Configuration page when an ANC stream is selected in the
Outputs widget. The same parameters can be accessed through the
Output/<output name>/Transport Stream ID: <n>/Service List/<service
name>/Component List/<component name> menu on the front panel.
Table 5.68 ANC component Parameters
Parameter Values Description
PID 32 to 8190 Sets the packet identifier associated with the component.
Bit Rate Weighting Fixed
Specifies the weight associated to the component in the
Bit Rate Tracking algorithm. For audio stream, this is Fixed
and read only.
5.5.3.3.6 PCR Stream Configuration
The video encoding module can generate a separate PCR stream. The PCR stream
contains timing reference that can be used for decoding the elementary streams
included in the same service as the PCR stream itself. To use the PCR stream as a
timing reference for decoding, set the PCR PID parameter associated with the
service to the PID assigned to the PCR stream.
The following parameters are available in Properties widget on the Service
Configuration page when a PCR Stream is selected in the Outputs widget. The
same parameters can be accessed through the Output/<output name>/Transport
Stream ID: <n>/Service List/<service name>/Component List/Slot <m> Video 1
PCR stream on PID <n> menu on the front panel.
Table 5.69 PCR Stream Configuration Parameters
Parameters Values Description
PID 16 - 8190
The packet identifier assigned to packets carrying the
program clock reference values.
Bit Rate Weighting Fixed
Not relevant for the PCR component. Read only
parameter.