Installing the Equipment
EN/LZT 790 0023/1 R16A
2-5
2.3.2 Data Ethernet Connector
The unit has four Ethernet ports - two for data input, and
two for data output and will respond to ARPs, pings and
other low-level Ethernet traffic. The ports are accessible
via RJ-45 connectors on the rear panel of the chassis.
These are labeled Ge 1, Ge 2, Ge 3 and Ge 4. Ge 1 and
Ge 2 are used for data input, while Ge 3 and Ge 4 are
data output.
Table 2.1 Data Ethernet Connector
Item Specification
Connector type RJ-45 (100/1000 Base T)
Connector designation Ge 1 (data input)
Ge 2 (data input)
Ge 3 (data output)
Ge 4 (data output)
Pin outs
(Unused pins are not connected)
Pin 1 - Tx Out (+)
Pin 2 - Tx Out (-)
Pin 3 - Rx In (+)
Pin 6 - Rx In (-)
Status and Activity Indication
Each Ethernet Data Port has a rear panel mounted status LED associated with it to
indicate link status, activity and speed as follows:
Table 2.2 Link Speed: Left (Green) LED
Link Speed LED Status
No Link Off
— — — — — — — — — — — — — — — — — —
100 Mbps Flash Off x 2
1000 Mbps Flash Off x 3
The left LED flash sequence period is 1 s, with a short flash duration of 100 ms.
Table 2.3 Link Activity: Right (Yellow) LED
Link Speed LED Status
No Link Off
— — — — — — — — — — — — — — — — — —
Link On
Activity Flash