EasyManua.ls Logo

Ericsson AVP 3000 Series - Page 482

Ericsson AVP 3000 Series
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Lists
E-26
EN/LZT 790 0023/1 R16A
Alarm Description Port Number Alarm ID Source Severity
Internal Packetizer Error
A packetizer error has occurred on
at least one stream.
1 010C0009
CE-x
Analogue
Module
warning
Video Processor Failure
An unrecoverable failure has
occured on the Video Processor.
The services are affected and
intervention is required. See log for
more details
1 010C000A
CE-x
Analogue
Module
critical
Video Processor Boot Failure
At least one video processor has not
booted
1 010C7FE0
Video
Module
critical
Video Processor Alive Count
Failure
At least one video processor has not
incremented its alive count
1 010C7FE1
Video
Module
critical
Video 1 Input Lock
No valid video found on video input.
Please check source connection.
1 010C4000
CE-x
Analogue
critical
Video 1 Logo display error
There has been a problem when
attempting to display the logo.
Please check the logo file that has
been uploaded and X,Y position.
1 010C4001
CE-x
Analogue
minor
VBI teletext not detected on
input
Unable to find teletext data on all of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
1 010C4008 VBI minor
VBI video index not detected on
input
Unable to find video index data on
any of the configured lines. Please
check the video input. For more
details on the type of VBI, see the
VBI status page.
1 010C4009 VBI minor
VBI CC608 closed captions not
detected on input
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
1 010C400A VBI minor
VBI ANC334 closed captions not
detected on input
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
1 010C400B VBI minor
VBI WSS not detected on input
Unable to find WSS (ETSI or AFD)
data on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
1 010C400C VBI minor
VITC not detected on input
Unable to find VITC data on any of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
1 010C400D VBI minor
Selected Time code source not
detected
For the selected Time code source
no Time code was found. If in auto
mode no source was found on any
input. Make sure that the correct
source is configured.
1 010C400E VBI minor
ANC Bar not detected on input
ANC Bar data extraction is on but no
ANC Bar data is present
1 010C400F VBI minor