Getting Started
3-78
1/1553-FGC 101 1790 Uen Y
Figure 3.73 Select the VBI Tab on the ANC Component Properties Widget
4. Turn Generic ANC Extraction to On.
5. Calculate the maximum anticipated bit rate considering the number of VANC
types expected to pass-thru on this component. One type typically takes around
90 kbps. Set this maximum into the Max ANC Bit Rate field.
3.7.31.2 How to Filter Data for a Generic ANC Component
To filter data for a generic ANC component:
1. Select the ANC component on the Output service. In the Properties widget,
select the VBI tab and open the Generic ANC accordion if the accordion is
closed.
2. If filtering is not required, select Off for the Generic ANC Filter Control. This will
cause all VANC types present on the input to be passed-thru on the ANC
component.
3. If the desire is to only allow certain VANC types to pass-thru on the ANC
component, and block all other VANC types, select Allow for the Generic ANC
Filter Control, and then follow step 5 to select the types that will pass-thru.