Web GUI Control
1/1553-FGC 101 1790 Uen Y
5-79
Table 5.61 Service Settings
Parameter Values Description
Service ID 1 - 65535
PMT PID 16 to 8190 The PID assigned to the Program Map Table for the service.
PCR PID 16 to 8190
The PID of the packetized elementary stream that transmits
the PCR for the current service.
BISS Key None, (Hidden) selected Key
The assigned security keys for the for Basic Interoperable
Scrambling System presets.
SDT Parameters
Provider The name of the service provider.
Name The service name as it appears in the PMT.
Service Type
Digital TV, Digital Radio, Teletext, Mosaic,
Data Broadcast
The type of service as transmitted in the PMT.
BISS Key None, (Hidden) selected Key
The assigned security keys for the for Basic Interoperable
Scrambling System presets.
Error Monitoring
Continuity Count Error
Threshold
1 to 1000 occurrences
Number of Continuity Count errors detected on the incoming
IP stream above which an alarm will be raised.
Continuity Count Error
Sampling Window
1 to 60 seconds
Time window in which the continuity count errors on the IP
input are counted.
Maximum Valid PID
Missing Period
1 to 10 seconds
Time threshold over which an alarm will be raised if a PID is
missing from the IP input.
(T/C) VCT Parameters
Short Name String Short description of the service.
Long Name String Long description of the service.
Major Channel
Number
1 to 99 PSIP major channel number.
Minor Channel
Number
1 to 99 PSIP minor channel number.
Service Type
Digital TV; Digital TV (H.264); Digital Radio;
Data Broadcast
Type of service. Does not affect encoding.
Source ID 0 to 65535 Source ID.
Hidden Yes; No
Hide Guide Yes; No
5.5.4.2 External PSIP Data Insertion
The External Program and System Information Protocol (PSIP) Data Insertion
feature allows the user to insert MPEG Program Specific Information (PSI) and
ATSC PSIP data generated by a Triveni Digital GuideBuilder
TM
equipment into any
of the internally created transport streams. The feature requires the AVP/SWO/PSIP
license to be installed on the unit.