Note: The STT table itself is generated by the Triveni Digital GuideBuilder, and the
generated table is updated with the UTC time on the AVP 4100 ATSC
Integrated System unit. UTC time can be configured by drilling down to
Encoder > Base Unit in the Advanced Video Processor Settings widget
on the Advanced tab of the Device Configuration page, and setting the
correct UTC time and date in the UTC Time and UTC Date fields in the
Properties widget. A time server can be set up in the SNTP Server field..
7. In the Minimum PID and Maximum PID fields, set the PID range for the
generated PSIP tables.
8. Configure the Triveni Digital GuideBuilder equipment as described in its user
manual. Make sure you apply the same transport stream and communication
settings as you did on the AVP 4100 ATSC Integrated System unit, otherwise
the embedded information will not reflect the structure of the internally created
transport stream.
Figure 5.30 Setting External PSIP Data Insertion on the GUI
5.5.4.3 Internal PSIP Data Insertion
The Internal Program and System Information Protocol (PSIP) Data Insertion feature
allows the user to insert internally generated MPEG Program Specific Information
(PSI) and ATSC PSIP data into any of the internally created Transport Streams.
The PSI information includes the following MPEG tables:
• Program Association Table (PAT)
• Program Map Table (PMT)