3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
Caution!
Wear a grounding wrist strap while unpacking,handling and
interconnecting the AXX 9100 CONNECT equipment modules, to
discharge any static buildup.
1.5.1 Mount the AXX 9100 CONNECT in a rack
Decide which side do you want to use as the front side (you can use
the side with the connectors or the Ericsson AXXESSIT branded
side as the front side) depends on if you have back access.
See Figure 2 and Figure 3
Figure 2 Branded side of the AXX 9100 CONNECT
Figure 3 Connector side of AXX 9100 CONNECT
1. Using attached screws, install the brackets on the left and right
side.
2. Move the AXX 9100 CONNECT to the desired rack position.
3. Align four M6 cage nuts in the equipment rack with the mounting
holes on the front of the AXX 9100 CONNECT.