3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
1.8.2 Alarm cable
Ericsson AXXESSIT AS does not provide an alarm cable. The
physical connector is a 9 pin DSUB. The alarm cable would typical
be used to connect the AXX 9100 CONNECT to the rack-top alarm
indicators or to external alarm input sources.
1.8.3 VT-100 cable
The cable connecting the AXX 9100 CONNECT to a workstation is
delivered with the AXX 9100 CONNECT Base Unit. This cable has
RJ-45 connector in one end and a 9 pins DSUB connector in the
other end. The length of the cable is 2m.
1.8.4 LAN cables
Use shielded cables for all LAN interfaces.
NOTE! Ordinary UTP cable can be used in Management port.
1.8.5 E1 cables
The E1 interfaces is default delivered with 120 Ohm. If 75 Ohm is
requried, external balun/patch panel can be delivered.
1.8.6 E3/T3
The Electrical interfaces for the AXX 9100 CONNECT E3/T3
module is based on the 1.0/2.3 coax connector.
1.8.7 Management cable
UTP Cable