39
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
By this command, TELNET and AXXCLI passwords can be
changed. Both passwords can be changed in the same command or
they can be changed one by one.
2.1.5 Erase a Community string
To remove a community string the following command can be used:
1. AXXCLI>Community-Handler\remove manager=0.0.0.0
community=public
2. Press Enter.
MANAGER: 0.0.0.0
COMMUNITY: public
removed.
2.2 Set up connection to a Network Element
The purpose of this section is to describe the tasks involved in
setting up a connection between the Craft Terminal and any network
element from Ericsson AXXESSIT. See also “Commissioning of IP
address via VT100 Interface” on page 2 -33. An Ethernet connection
to the MGMT port is required instead of the VT100 connection that
is used in previous sections of the manual
2.2.0.1 Start AXX 9820 CRAFT on your computer
1. Replace the VT100 connection previous used, with an Ethernet
connection to the MGMT port .
2. Select Start>Programs>AXX 9820 CRAFT>AXX 9820 CRAFT
Figure 19 Starting AXX 9820 CRAFT