AXX 9100 CONNECT R1.2 Quick Reference Guide
3/1531-ZAP 701 14/1 Uen A 2006-10-16
44
2.4 Further configuration
2.4.1 Recommended order
• Download licenses if needed and not present already from
factory. E.g. OSI , STM-4
• Configure expected module
• Enable alarm-reporting on all modules including the power
module(s)
• Adjust time and date and optionally the Time Server
• Add community string reflecting the IP address of your AXX 9820
CRAFT PC
• If your configuration includes SDH interfaces, enable all in use
• Configure synchronisation as planned
• Configure DCN if not including signals through IP-payload
• If your configuration includes SDH interfaces structure the VC's
as desirable
• If your configuration includes Ethernet into SDH configure
administratively the desired bandwidth for WAN-port(s)
• If your configuration includes PDH interfaces enable and
configure desirable port(s)
• If your configuration includes Ethernet consider the following;
operation of each Ethernet-port, VLAN-table, STP etc.
• Circuit provisioning including cross-connections
• Configure protection SNCP and MSP if needed
• Consider performing configuration back-up
2.4.2 Further reading
Please see the AXX 9820 CRAFT User Guide for instructions
related to further configuration and the AXX 9100 CONNECT
Technical Reference for details concerning the equipment.