Connector disposition
The OEM connector is a 25-pole D-sub female connector, mounted on the
rear of the F800. The connector disposition is as follows:
Pin Signal name Electrical
level
Comments
1 TX +12V Outputs 12V at transmit
2 TX Data -10dBm Data input to transmitter
3 0V 0V Common ground
4 PTT +12V Connect to 0V for transmit
5 RX Data -10dBm Data output from receiver
6 +12V +12V 12 VDC output max 1000mA
7 SQ +12V Squelsh open collector
8 +5V ext +5V 5V DC output max 1000 mA
9 TX line -10dBm AF input to transmitter
10 RX line -10dBm AF output from receiver
11 CH 1 +12V 0=active Binary channel select bit 1
12 CH 2 +12V 0=active Binary channel select bit 2
13 CH 4 +12V 0=active Binary channel select bit 4
14 CH 8 +12V 0=active Binary channel select bit 8
15 Spare Not used
16 CH 16 +12V 0=active optional
17 CH 32 +12V 0=active optional
18 CH 64 +12V 0=active optional
19 CH 128 +12V 0=active optional
20 Spare Not used
21 Spare Not used
22 Spare Not used
23 Spare Not used
24 Spare Not used
25 Spare Not used