LIGHTNING PROTECTION FOR MASTS
8 (8)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ECS/S/LT Magnus Lindahl ECS/S/LT-96:5037
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ECS/S/LTC 1996-06-04 A
Error! Unknown switch argument.
Low voltage input
See Figure 3.
Incoming low-voltage inputs, usually telephone lines must, if not an earth cable, be
protected by lightning protection RR-192500. This is a surge and transient protection.
Assembly must be such that there is no obvious fire hazard.
The earth connection must be to the earth electrode system or common earth
terminal.
The connecting leads must be at least 6 mm copper and insulated.
Figure 3. Low voltage input