Transmission Interface Handling DS1 1544 kbit/s
The parameter N1 defines the threshold numbers for SES.
Value range is 1-1000
Default value is 320
The configuration parameter T
The parameter T defines the time interval for ERATE
supervision
Value range is 1-5 s
Default value is 2 s
The configuration parameter AFT
The configuration parameter AFT defines the Alarm
Filtering Time for all the fault supervision functions
except RAI supervision
Value range is 50-5000 ms
Default value is 125 ms
The resolution is 1 ms, but the accuracy is ±25 ms
The configuration parameter AFT RAI
The configuration parameter AFT RAI defines the Alarm
Filtering Time for the fault supervision function RAI
supervision
Value range is 50-5000 ms
Default value is 125 ms
The resolution is 1 ms, but the accuracy is ±25 ms
Base interval for ES, SES, UAS, BFF and SF
Valid values: 60 and 126 seconds. The value 126
seconds must be used when BFF supervision is activated
in the BSC.
Base interval for DF and SF
Value range: 1-24 h
33.3.7 Multidrop Layer 1
For an RBS configured for multidrop, the function is initiated during
restart of CMRU.
For an RBS not configured for multidrop, the function is initiated when
the parameter Network Topology is set by the OMT to indicate
multidrop (cascade).