1. On the PC, start HyperTerminal and make a new connection or session,
saving it with the following attributes (in this example, the COM1 port on
the PC is used):
Name: terminal_9600
Connect using: Direct to Com1
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: none
1. Press ENTER to start a CLI session.
13.3 Using Telnet
Prerequisites
To be able to connect to the switch remotely, the switch has to have the
following basic configuration:
IP address, subnet mask and default gateway.
One Ethernet port connected to the Management VLAN, for example, the
uplink port 25.
Start a Telnet session in Windows by clicking Start Run…, type