EasyManua.ls Logo

Ericsson MD110 - 5 Administration and Example Programming; Administration Suggestions

Ericsson MD110
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADMINISTRATION AND EXAMPLE PROGRAMMING LBI-39039B
21
5. ADMINISTRATION AND EXAMPLE PROGRAMMING
This section is intended to outline the items needing consideration when configuring an MD110 and is not intended to be
all-inclusive. The MD110 manual set is composed of several volumes and could not be adequately compressed here. This
Jessica configuration provides telephone interconnect between EDACS and the PSTN. It includes a minimum number of
analog extensions for testing. If the customer requires connection of Jessica to another PBX, or wishes to use the MD110 as
the business PBX, this configuration may be significantly altered and may require the assistance of an MD110 qualified
systems engineer. Pointers for customizing the MD110 for these cases are herein.
5.1. ADMINISTRATION SUGGESTIONS
The following organization is used for the Public Network configuration and the PBX Network configuration described
in sections 6 and 7, respectively. The rationale is to make the Trunk Call Discrimination (TCD), Traffic Matrix Group
(TMG), and Common Abbreviated Dialing (CAD) categories the same number for particular groups in the system. This
simplifies the MD110 administrator's task. These are explained in detail later along with the Route and LCR choices.
TCD, TMG, and CAD CATEGORY
TCD TMG CAD
Extensions 0 0 0
EDACS Routes 1 1 1
Private Network Routes 2 2 2
Public Network Routes 3 3 3
Assigning entries to TCD or TMG Category 15 allows maximum privileges, which can result in telephone fraud.
If any extension groups with different calling privileges are added, it is recommended that their TCD or TMG
category should begin at 5 and use 6, 7, 8, ...
If any additional EDACS, Private Network, or Public Network Routes (trunk groups) with different calling privileges
are added, begin at 14 and use 13, 12, 11, ...
It is unlikely that many of these options will be added, and minimizing the number of these categories will simplify
the MD110 administrator's task.
CAD only contains 4 classes
ROUTES
Route Number External Destination Code
EDACS 10-19 670-679
Private Network 20-29 680-689
Public Network 30-39 690-699
NOTE

Table of Contents