ADMINISTRATION AND EXAMPLE PROGRAMMING LBI-39039B
39
5.8. AUTHORIZATION CODES
EZDISA Access
Requires software patch 34180.
Inbound interconnect calls to the DISA number allow dialing a radio without entering an Authorization Code.
An Authorization Code can allow greater calling privileges. Normally, this feature is not used.
DISA Access
Inbound interconnect calls to the DISA number require an Authorization Code before dialing a radio.
Creating Authorization Codes that have a Common Class of Service
1. Allow CAD numbers to the Public Network.
2. Have TMG that allow connection to the Public Network.
3. Have TCD Category that allows dialing of Public Network LCR codes or Public Network External Destination codes.
4. May result in telephone fraud if the codes are used by unauthorized callers.
AUCOI
AUTH
Authorization Code
XXXX XXXX must be entered in the script file and will be 1 to 7 digits in
length, with the first digits being other than 0
CILCOD
Call Information Logging
Number
XXXX XXXX must be entered in the script file and will be 1 to 6 digits
CAT
Common Class of Service
Category
XX XX must be entered in the script file and will be 0 to 63; the
Common Class of Service category must be defined
CHECK NO Code does not have to match extension