LBI-39039B LIM CONFIGURATIONS FOR PUBLIC NETWORK CONNECTIONS
54
6.4.2. Route Data
RODAI
ROU 3X This information will match the entry under
ROCAI.
TYPE TL1 TLU-41 trunk
VARC
Constant 0000000
Characteristics 6 Common Control CO
Loop start
VARI
Constant 0000000
Characteristics 2 Loop start
Clear signal incoming
VARO
Constant 0000000
Characteristics D Dial tone from public exchange
DTMF
Clear signal outgoing
No B-answer signal
6.4.3. Route Equipment
ROEQI
ROU 3X This information will match the entry under
ROCAI.
TRU
LIM-Trunk 1-1&&1-X X is a function of the number of trunks and can
not be greater than 4.
EQU
LIM 1
Magazine X This information must be added to the script
file.
Board position XX This information must be added to the script
file.
Board Circuit No. 0 First circuit on board