EasyManua.ls Logo

Ericsson MINI-LINK TN R3 ETSI - 3.2 Access Module Magazine (AMM)

Ericsson MINI-LINK TN R3 ETSI
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic Node
Line
Interface
Radio
Modem
LTU
Radio
Modem
ATM Ethernet ADM
Ethernet ADM
Services
Line interface
PTP Connections
9746
Figure 8 PTP C onnections
3.2 Access Module Magazine (AMM)
The indoor part consists of an Access Module Magazine (AMM) with plug-in
units. This section describes the AMM types and their associated cooling and
power supply functions.
3.2.1 AMM 2p and AMM 2p B
AMM 2p is suitable for end site and repeater site applications. There are two
models:
AMM 2p has two half-height slots equipped with one NPU2 and the optional
LTU 12/1 Kit.
AMM 2p B has two half-height slots equipped with one NPU3 and the
optional LTU3 12/1.
Two full-height slots can be equipped with MMU, LTU or ETU. The height of
an AMM 2p or an AMM 2p B is 1U.
The FAU4 is used depending on the configuration, see Section 3.2.1.2 on
page 13.
AMM 2p and AMM 2p B can be fitted in a standard 19" or metric rack or on a
wall using a dedicated mounting set.
11
4/1555-CSH 109 32/1-V1 Uen B 2007-09-14

Related product manuals