EasyManua.ls Logo

Ericsson MINI-LINK TN R3 ETSI - Page 41

Ericsson MINI-LINK TN R3 ETSI
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic Node
3.6.3.1.4 Control and Supervision
This block interfaces the PCI bus and handles control and supervision. Its main
functions are to collect alarms, control settings and tests.
The block communicates with the NPU over the PCI bus.
3.6.3.1.5 SPI
This block interfaces the SPI bus and handles equipment status. Failure is
indicated by LED’s on the front of the unit.
3.6.3.1.6 Power
This block interfaces the Power bus and provides secondary voltages for the
unit. All plug-in units have a standard power module providing electronic soft
start and short circuit protection, filter function, low voltage protection, DC/DC
converter and a pre-charge function.
35
4/1555-CSH 109 32/1-V1 Uen B 2007-09-14

Related product manuals