RBS 2308 and RBS 2309 User’s Guide
5.4.12.3 Splitting/Highway Function
1.
Connect the cable between
connection port TX(/RX) and
LOAD on both the MCBs.
P010564A
ANT 1
ANT 2
TX(/RX)
LOAD
TX(/RX)
MCB
2.
Remove the protection covers from connector TX(/RX) 1 and TX(/RX) 2
on the RRU. Install the MCBs to the connection ports. Fasten each of
them with two s hort screws.
P010558B
ANT 1
ANT 2
TX(/RX)
LOAD
TX(/RX)
MCB
3.
Connect the antenna cables to connection ports ANT 1 and ANT 2
on both MCBs.