Installation Instruction
Figure 6 Cabinet and Roof Attachment
3.3 Earth Grounding the Cabinet
Do!
Products not connected to ground risk being damaged by overvoltage or
overcurrent. Always connect products to ground according to instructions.
For general information about earth grounding principles, see Grounding
Guidelines for RBS Sites.
For information about installing earth grounding, see Grounding Material
Installation Instruction.
To connect the earth grounding cable to the RBS 3107, do the following:
1. Remove the six screws holding the Distribution Frame (DF) in place, using
a T30 Torx screwdriver, and push it to the left as shown in the figure below.
10
1/1531-COH 109 2073 Uen H 2006-11-06