Procedure
3.7.3 Connecting Transmission Cables, Coaxial, 75
, Unbalanced (E3,
T3) - Alternative 3
Figure 54 Possible OVP Module Positions
To connect a coaxial cable to an Overvoltage Protection (OVP) module, do
the following:
1. Ensure that the DF is not fastened in place, and that the space beneath it is
accessible. See Section 3.3 on page 10.
2. Remove the rubber sealing in the DF cable entry closest to the OVP
module to be used.
3. Insert the cable with its cable gland (1) and tighten it with a 20 mm
open-ended wrench (2). See figure below.
Note: The cable is a dual coaxial cable, that is, the cable consists of two
coaxial parts.