Procedure
P014479C
1
3
5
2
4
6
Figure 68 RF Cables
4. Press each cable into the gasket of the cable inlet in the order indicated
in the figure above.
5. Check that each cable is as straight as possible and make necessary
adjustments. No sharp bends in cables are allowed close to connectors.
Note: Do not exceed the minimum bending radius for the cables.
6. Ensure that the internal cables of the FUs have not been accidentally
loosened.
7. Plug the open holes in the gasket with the supplied plugs.
Note: No holes must be left open.
8. Attach the front part of the cable inlet as shown in the figure above. Tighten
the screws, using T8, T15 and T30 Torx screwdrivers.
3.12 Powering Up the RBS
Do!
Products not connected to ground risk being damaged by overvoltage or
overcurrent. Always connect products to ground according to instructions.
551/1531-COH 109 2073 Uen H 2006-11-06