Loading...
Managing Hardware with CLI Commands
Determining Operating Status 5-21
Table 5-26 lists the two-character product codes (the first two characters in the serial number) that identify
the SmartEdge 1200 chassis types.
Table 5-27 describes the output fields for the show hardware command (in any mode) with the detail
keyword; fields are listed in alphabetical order. This command displays information only for those units
that are installed in the chassis, and in most cases, displays only the fields that are applicable to the type of
card.
Table 5-26 Product Codes for SmartEdge 1200 Chassis Types
Product Code Chassis Model
D7 Standard SmartEdge 1200s chassis.
D9 NEBS-compliant SmartEdge 1200n chassis
Table 5-27 Output Fields for the show hardware Command with the detail Keyword
Field Description
Active Alarms
1
Alarm conditions for this unit:
NONE—No alarm conditions exist.
condition—Alarm condition is in effect.
For a complete list of conditions that can cause an alarm, see Appendix B, “Alarms and Probable Causes.”
Air filter date yyyy-mm—Date the air filter is due to be replaced.
Card Status For traffic cards only:
FPGA mismatch—Card needs an FPGA upgrade.
FPGA upgrade—FPGA upgrade has been started.
HW detected—Card is detected and being initialized.
HW failure—Card has experienced a failure.
HW initialized—Card is initialized and ready.
Chass Entitlement Type of chassis for which this card is intended:
All—Card is entitled in every chassis.
SE1200—SmartEdge 1200 chassis only.
List of chassis, separated by slashes (/)—Listed chassis only.
Chassis Type SE1200—Backplane is installed in a SmartEdge 1200 chassis.
CLEI Code Common Language Equipment Identifier (CLEI) code for this small form-factor pluggable (SFP) optical
transceiver; blank if not applicable for this transceiver.
DimFpga rev
DimFpga file rev
Dim FPGA revision and file revision; N/A or not displayed if not applicable for this card.
EEPROM id/ver nnnn/n—Version of the unit EEPROM.
EPPA memory nnn MB—Size of egress PPA memory.
Fan Tray Status Present—Fan tray is installed.
Fan(s) Status Failed—At least one fan is not working.
Normal—All fans are working.
FlipFpga rev FLIP FPGA revision and file revision; N/A or not displayed if not applicable for this card.
Forte2Fpga rev Forte2 FPGA revision and file revision; applicable to XCRP3 only. This FPGA controls power on/reset for all
devices.
ForteFpga rev Forte FPGA revision and file revision; applicable to XCRP only. This FPGA controls power on/reset for all
devices.

Table of Contents