7. Installation
7.1.1. Installation Safety Instructions
The unit must be installed by a suitably qualified person in accord-
ance with the latest IEE Wiring Regulations. Isolate mains supply
before commencing installation. Please read all instructions before
proceeding.
Ensure that the fixed wiring connections to the mains supply is via a
fuse rated at not more than 3 Amps and Class ‘A’ switch having a
contact separation of a minimum of 3mm in all poles. The recom-
mended cable sizes are 1.0mm sqr or 1.5mm sqr. No earth connec-
tion is required as the product is double insulated but ensure
continuity of earth throughout the system.
7.1.2. General Safety Instructions
This product complies with the essential requirements of the follow-
ing EC Directives:
• Electro-Magnetic Compatibility Directive
2014/30/EU
• Low Voltage Directive
2014/35/EU
• EC Marking Directive 2014/30/EU
Please leave the user instructions with the end user where they
should be kept in a safe place for future reference.
14
7.1.3 Warning Notices
WARNING: ALWAYS ISOLATE THE AC MAINS SUPPLY
BEFORE INSTALLING.
THIS PRODUCT MUST BE FITTED BY A COMPETENT PERSON,
AND INSTALLATION MUST COMPLY WITH THE GUIDANCE
PROVIDED IN THE CURRENT EDITIONS OF BS767 (IEE WIRING
REGULATIONS) AND PART “P” OF THE BUILDING REGULA-
TIONS.