ETS Series AC Servo User's Manual
- 103 -
6.2 MODBUS Communication Related Parameters
Parameter No.
Description
Setting
Validation
Control Mode
Meaning
Pn700
Hex
After restart
ALL
Pn700.0 MODBUS baud rate
[0] 4800bps
[1] 9600bps
[2] 19200bps
[3] 38400bps
[4] 57600bps
[5] 115200bps
Pn700.1 Communication protocol
selection
[0] 7N2MODBUS,ASCII
[1] 7E1MODBUS,ASCII
[2] 7O1MODBUS,ASCII
[3] 8N2MODBUS,ASCII
[4] 8E1MODBUS,ASCII
[5] 8O1MODBUS,ASCII
[6] 8N2MODBUS,RTU
[7] 8E1MODBUS,RTU
[8] 8O1MODBUS,RTU
Pn700.2 Communication protocol
selection
[0] SCI communication with no
protocol
[1] MODBUS SCI communication
Pn700.3 Reserved
Pn701
Axis address
After restart
ALL
Axis address of MODBUS protocol
communication