ETS Series AC Servo User's Manual
3.2.3 I/O Signal Names and Functions
Control power supply input for I/O signals: Provide the +24V DC power supply
Servo ON:Turns the servomotor on.
The function of I/O are default,it can be
changed by setting parameters.
It has deferent means depends on deferent
control mode.
Alarm reset: Releases the servo alarm state.
Positional error pulse clear input: Clear the
positional error pulse during position control.
Forward external torque limit
Reverse external torque limit
Power supply input for open collector reference(pulse)
Power supply input for open collector reference(direction)
Reference pulse input
Reference sign input
Pulse reference input mode:
Sign + pulse train
CCW + CW pulse
Two-phase pulse
Positioning completion(Speed coincidence):
Turns ON when the number of positional error
pulses reaches the value set.
The function of I/O are default,it can be
changed by setting parameters.
Motor rotation detection: when the servomotor
is rotating at a speed higher than the motor
speed setting.
Servo ready:
ON if there is no servo alarm when the
control/main circuit power supply is turned ON.
Servo alarm:
Turns off when an error is detected.
Converted two-phase pulse(phases A
and B) encoder output.
Zero-point pulse(Phase-C) signal
Connect frame to ground if the shield wire of the I/O signal cable is connected to the