Loading...
ETS Series AC Servo User's Manual
- 35 -
x
Noise
Filter
Ground plate
Separate these circuits
Noise
Filter
Noise
Filter
Noise
Filter
Ground plate
Ground plate
Ground plate
Separate the noise filter ground wire from the output lines.
Do not accommodate the noise filter ground wire, output lines and other signal lines in the same duct or bundle them
together.
X
Noise
Filter
Ground plate
Noise
Filter
Ground plate
Connect the noise filter ground wire directly to the ground plate. Do not connect the noise filter ground wire to other
ground wires.
Noise
Filter
ground plate
Shielded
ground wire
servodrive
stub
x
Noise
Filter
servodrive
servodrive servodrive
ground plate
If a noise filter is located inside a control panel, connect the noise filter ground wire and the ground wires from other
devices inside the control panel to the ground plate for the control panel first, then ground these wires.