ETS Series AC Servo User's Manual
- 83 -
Start
Operate with factor setting.
Set Pn100=1
Operation OK
Continuous online autotuning
Pn100=123456
Operation OK?
Adjust the machine rigidity setting
Set at Pn101
Operation OK
Do not perform online autotuning.
Set Pn100=0
End
Yes
No
No
No
No
Yes
Yes
Yes
Load moment of inertia
varies?
4.9.3 Setting Online Autotuning
Related parameters:
Parameter
No.
Name
Unit
Setting
Range
Factory
Setting
Setting
Invalidation
Pn100
Online autotuning setting
0:Manual gain adjustment
1,2,3=Normal mode;4,5,6=Vertical load
0~6
0
After restart