5.2 Operation in Utility Function Mode
In utility function mode, the panel operator can be used to run and adjust the servo drive and servomotor.
The following table shows the parameters in the utility function mode.
5.2.1 Alarm Traceback Data Display
The alarm traceback display can display up to 10 previously occurred alarms.The alarm is displayed on Fn000, which is
stored in the alarm traceback data.
Follow the procedures below to confirm alarms which have been generated.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the function number of alarm traceback data display.
3. Press the ENTER key once, the latest alarm data is displayed.
Alarm Sequence NumberAlarm Code
4.Press the INC or DEC key to display other recent alarms that have occurred.
5. Press the ENTER key, the display will return to Fn000.
Note: Hold the ENTER key for one second with alarm code displaying, all the alarm traceback datas will be cleared.
Parameter No.
Function
Fn000
Alarm traceback data display
Fn001
Parameter setting initialization
Fn002
JOG mode operation
Fn003
Reserved
Fn004
Reserved
Fn005
Automatic adjustment of servomotor current detection
Fn006
Manual adjustment of servomotor current detection
Fn007
Software version display
Fn008
Position teaching
Fn009
Static inertia detection
Fn010
Reserved
Fn011
Reserved
Fn012
Reserved
Fn013
Parameters copy
Fn014
Reserved

Table of Contents