ProNet Plus Series AC Servo User's Manual
- 118 -
Chapter 5
Panel Operator
5.1Basic Operation
5.1.1 Functions on Panel Operator
The panel operator is a built-in operator that consists of display section and keys located on the front panel of the servo
drive.
Parameter setting, status display ,and execution of utility function are enabled using the panel operator.
The names and functions of the keys on the panel operator are shown as follows:
MODE INC DEC ENTER
Note: In this manual, the Panel Symbol is represented by Corresponding Key Name for easy understanding.
5.1.2 Resetting Servo Alarms
Servo alarms can be reset by pressing the ENTER key when the panel operator in display mode. Servo alarms can also
be resetusing the CN1-39(/ALM-RST) input signal.
There is no need to clear the servo alarms if it turns the main circuit power supply OFF.
Note: After an alarm occurs, remove the cause of the alarm before resetting it.
Panel
Symbol
Corresponding
Key Name
Function
INC key
·To display the parameter settings and setting values.
·To increase the setting value.
·To decrease the setting value.
DEC key
M
MODE key
·To select a basic mode, such as the display mode, parameter setting
mode, monitor mode, or utility function mode.
·To save the setting during parameter setting and exit.
ENTER key
To display the parameter settings and setting values, and release ararm.