EasyManua.ls Logo

Estun ProNet-15D - Parameters in Detail(Pronet-□□□EG-EC)

Estun ProNet-15D
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Plus Series AC Servo User's Manual
- 192 -
A.4 Parameters in detail(ProNet-□□□EG-EC)
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
Pn000
Binary
After restart
ALL
Pn000.0 Servo ON
[0] External S-ON enabled.
[1]External S-ON disabled. Servomotor excitation
signal is turned ON automatically after S-RDY is
output.
Pn000.1 Forward rotation input signal prohibited
(P-OT)
[0]External P-OT enabled. Operate in the time
sequence setting in Pn004.0 when travel limit occurs.
[1] External P-OT disabled.
Pn000.2 Reverse rotation input signal prohibited
(N-OT)
[0]External N-OT enabled. Operate in the time
sequence setting in Pn004.0 when travel limit occurs.
[1] External N-OT disabled.
Pn000.3 Alarm output when instantaneous power
loss (ALM)
[0]Instantaneous power loss for one period with no
alarm output
[1]Instantaneous power loss for one period with alarm
output
Pn001
Binary
After restart
Pn001.0
ALL
Pn001.1
T
Pn001.2
P, S
Pn001.3
P
Pn001.0CCW,CW selection
[0] Sets CCW as forward direction
[1] Sets CW as forward direction
Pn001.1 Analog speed limit enabled
[0] Sets the value of Pn406 as the speed limit
valueduring torque control.
[1]Use the lower speed between V-REF and Pn406 as
an external speed limit input.
Pn001.2 Analog torque limit enabled
[0] Sets Pn401~Pn404 as torque limit.
[1]Sets the value corresponding to Tref input analog
voltage as torque limit.
Pn001.3 2nd electronic gear enabled
[0]2nd electronic gear is disabled, PCON signal is
used toswitch P/PI
[1]2nd electronic gear is enabled, PCON signal is only
used as 2nd electronic gear when Pn005.1 is set to 1.
Pn002
Binary
After restart
ALL
Pn002.0Electronic gear switching mode
[0]Corresponding time sequence

Table of Contents

Related product manuals