ProNet Plus Series AC Servo User's Manual
I/O signal power supply 24V
DC
Note:The functions allocated to the following input and output signals can be changed by using the parameters.
·Input signals:/S-ON,/P-CON,P-OT,N-OT,/ALM-RST,/CLR,/PCL,/NCL,SHOM,ORG
·Output signals:/TGON,/S-RDY,/COIN,/HOME
Please refer to A.3 Parameters in details for detailed information.
3.2.4 Interface Circuit
This section shows examples of servo drive I/O signal connection to the host controller.
■Interface for Analog Reference Input Circuit
Analog signals are either speed or torque reference signals at about 40kΩimpedance, and the maximum allowable
voltages for input signals is ±10V.
Reference speed input Reference torque input
10V
470Ω(1/2W)min.
1
2
3
2KΩ
V-REF
GND
About 40KΩ
0V
Servodrive
10V
470Ω(1/2W)min.
1
2
3
2KΩ
T-REF
GND
About 40KΩ
0V
Servodrive
■Interface for Sequence Input Circuit
The sequence input circuit interface connects through a relay or open-collector transistor circuit.Select a low-current relay
otherwise a faulty contact will result.
Servodrive
3.3KΩ
+24VIN
/S-ON,etc.
DC24V
50mA min.
Servodrive
3.3KΩ
+24VIN
/S-ON,etc.
DC24V
50mA min.