EasyManua.ls Logo

Estun ProNet-15D - Absolute Encoders

Estun ProNet-15D
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Plus Series AC Servo User's Manual
- 70 -
Parameter Pn511 description as following:
0
/COIN(/V-CMP)output
1
/TGON rotation detecting output
2
/S-RDY servo drive get ready output
3
/CLT torque limit output
4
/BK brake interlock output
5
/PGC encoder C pulse output
6
OT overtravel signal output
7
/RD servo enabled motor excitation output
8
/HOME home completion output
9
/TCR torque detection output
A
R-OUT1 remote output1
B
R-OUT2 remote output2
Related parameter:
Parameter
No.
Name
Unit
Setting
Range
Default
Pn505
Servo ON waiting time
ms
-2000~2000
0
Pn506
Basic waiting flow
10ms
0~500
0
Pn507
Brake waiting speed
rpm
10100
100
Pn508
Brake waiting time
10ms
10100
50
(4) Setting the Brake ON/OFF Timing after the Servomotor Stops
With the factory setting, the /BK signal is output at the same time as the servo is turned OFF. The servo OFF timing can be
changed with a parameter.
Pn505
Servo ON waiting time
Setting Range
Setting Unit
Factory Setting
Setting Validation
-20002000
ms
0
Immediately
Pn506
Basic waiting flow
Setting Range
Setting Unit
Factory Setting
Setting Validation
0500
10ms
0
Immediately

Table of Contents