ProNet Plus Series AC Servo User's Manual
- 105 -
-60006000
rpm
-200
Immediately
Pn321
Internal set speed 6
Setting Range
Setting Unit
Factory Setting
Setting Validation
-60006000
rpm
-300
Immediately
Pn322
Internal set speed 7
Setting Range
Setting Unit
Factory Setting
Setting Validation
-60006000
rpm
500
Immediately
NOTE: the servomotor’s maximum speed will be used whenever a speed setting for the Pn316Pn322 exceeds the
maximum speed.
4.8.2 Input Signal Settings
The following input signals are used to switch the operating speed.
Type
Signal Name
Connector Pin Number
Meaning
Input
/P-CON
CN1-15
Selects the internally set speed.
Input
/P-CL
CN1-41
Selects the internally set speed.
Input
/N-CL
CN1-42
Selects the internally set speed.
4.8.3 Operating Using an Internally Set Speed
Use ON/OFF combinations of the following input signals to operate with the internally set speeds.
When Pn005.1=3: Selects the internally set speed (contact reference) Speed control (zero reference)
Input Signal
Speed
/P-CON
/P-CL
/N-CL
OFF(H)
OFF(H)
OFF(H)
Speed control (zero reference)
OFF(H)
ON(L)
SPEED1
ON(L)
OFF(H)
SPEED2
ON(L)
ON(L)
SPEED3
ON(L)
OFF(H)
OFF(H)
SPEED4
OFF(H)
ON(L)
SPEED5
ON(L)
OFF(H)
SPEED6
ON(L)
ON(L)
SPEED7
Note: OFF= High level; ON= Low level
speed
speed