ProNet Plus Series AC Servo User's Manual
4.11.5 Over travel signal output(OT)
Not including this
setting in the default
setting,please choose
terminal output by
setting parameter
Pn511
Without forward rotation
Prohibited(POT)and reverserotation
prohibited(NOT)signal
With forward rotation
Prohibited(POT)and reverse rotation
prohibited(NOT)signal
When machine is on over travel state,OT signal is OFF;Host controller can use this signal to stop sending
reference.
Related parameter
Pn000.1=1,external POT disabled;Pn000.2=1, external NOT disabled;
Pn000.1=1 and Pn000.2=1,OT signal is ON.
4.11.6 Servo Enabled Motor Excitation Output(/RD)
Not including this setting in
the default setting,please
choose terminal output by
setting parameter Pn511
Servo enabled motor excitation
Servo disabled motor not excitation
/RD is on when servo enabled motor excitation.
4.11.7 Torque Limit DetectionOutput (/CLT)
The application ofoutput signal /CLT is as follows:
Speed, torque control, position control
24V Power
supply
+24V
Servo Drive
1CN-
1CN-
/CLT+
/CLT-
Photocoupler output
Max.applicable Voltage:
DC30V
Max.applicable current:
DC50mA