ProNet Plus Series AC Servo User's Manual
Servomotor overloading proportion
Servomotor winding temperature
High 16 bits of the encoder rotation
pulse number
Used in conjunction with 080A
MODBUS communication IO signal
Donot save whenpower off.
Version is expressed by digit.
Version is expressed by digit.
Encoder multi-turn information
Encoder single-turn information
Encoder single-turn information high
bits
01:Forward rotation
00:Stop
01:Reverse rotation
00:Stop
JOG forward rotation at node
position( start signal has been set)
01:Forward rotation
00:Stop
JOG reverse rotation at node
position(start signal has been set)
01:Reverse rotation
00:Stop
Clear encoder multi-turn data
Position teaching function
Note:
1. Parameter area (communication address 0000~00DE
H
)
Parameter address is relevant to the parameters in the parameter list.
For example, parameter Pn000 is relevant to communication address 0000
H
; parameter Pn101 is relevant to
communication address 0065
H
. Read/write operation to address 0000
H
is the read/write operation to Pn000. If the
communication input data is not within the parameter range, the data will be aborted, and servo drive will return an
operation unsuccessful signal.
2. Alarm information storage area (07F1~07FA
H
)
Historical alarm 1
(the latest alarm)