EasyManua.ls Logo

Estun ProNet-30D - 3.1 Main Circuit Wiring

Estun ProNet-30D
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProNet Plus Series AC Servo User's Manual
- 23 -
Chapter 3
Wiring
3.1 Main Circuit Wiring
Please observe the following instructions while wiring the main circuit.
CAUTION
·Do not bundle or run power and signal lines together in the same duct. Keep power andsignallines
separated by at least 300 mm.
·Use twisted-pair shielded wires or multi-core twisted-pair shielded wires for signal and encoder feedback
lines.
·The maximum length is 3 m for reference input lines and 20 m for encoder feedback lines.
·Do not touch the power terminals for 5 minutes after turning power OFF because high voltage may still
remain in the servo drive.
3.1.1 Names and Functions of Main Circuit Terminals
Terminal
Symbol
Name
Main Circuit
Voltage(V)
Servo Drive
Model
ProNet-
Functions
L1,L2,L3
Main circuit
power supply
input terminal
200
A5A-04A
Single-phase 200230VAC +10%-15% (50/60Hz)
200
08A-50A
Three-phase 200230VAC +10%-15% (50/60Hz)
400
10D-50D
Three-phase 380440VAC +10%-15% (50/60Hz)
FG
FG
200
A5A-04A
Normally not connected.
U,V,W
Servomotor
connection
terminals
Connect to the servomotor.
L1C,L2C
Control circuit
power supply
input terminal
200
A5A -50A
Single-phase 200230VAC +10%-15% (50/60Hz)
24V,GND
400
10D-50D
24VDC +10%-10%
Ground terminals
Connects to the power supply ground terminals
and servomotor ground terminal.
B1,B2,B3
External
regenerative
resistor
connection
terminal
200
A5A -04A
Connect an external regenerative
resistor(provided by customer) between B1 and
B2.
200
08A-50A
If using an internal regenerative resistor, please
short B2 and B3. Remove the wire between B2

Table of Contents