ProNet Plus Series AC Servo User's Manual
Servo Drive
Model
ProNet-
and B3 and connect an external regenerative
resistor(provided by customer) between B1 and
B2, if the capacity of the internal regenerative
resistor is insufficient.
DC reactor for
harmonic
suppression
terminal
Normally short○+ 1and○+ 2.
If a countermeasure against power supply
harmonic waves is needed, connect a DC reactor
between○+ 1and ○+ 2.
Main circuit
minus terminal
3.1.2 Typical Main Circuit Wiring Examples
Single-phase 200V ProNet-A5A~04A
L1 L2
Single-phase 200~230V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
W
V
U
M
PG
A(1)
B(2)
C(3)
D(4)
L2C
L1C
CN2
1Ry
1D
+24V
0V
1Ry
1PL (Servo Alarm Display)
ALM+
ALM-
ProNet
Series Servodrive
1
2
Ground Terminal
Encoder
Servodrive
Magnetic Contactor
Molded-case Circuit Breaker
Surge Protector
Noise Filter
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay.
B1
B2
B3
B1
B2
B3
External regenerator resistor
Note
1.The L1,L2,L3 and L1C,L2C terminals wiring method of ProNet-A5A~04Aservo drives is different from other ProNet
series servo drives. Please note the specific terminal definition while wiring.
2.The main circuit power supply of ProNet-A5A~04A is Single-phase 200V.
3.External regenerative resistor for ProNet-A5A~04A is provided by customer, the model of 60W,50Ωresistor is
recommended.
4.Change Pn521.0 from “1” to “0” when using the external regenerative resistor in ProNet-A5A~04A servo drives.