ProNet Plus Series AC Servo User's Manual
- 25 -
Three-phase200V ProNet-08A50A
Noise Filter
L1 L2 L3
Three-phase 200~230V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
L3
W
V
U
M
PG
Servomotor
Encoder
A(1)
B(2)
C(3)
D(4)
L2C
L1C
CN2
1Ry
1D
+24V
0V
Surge Protector
Magnetic Contactor
Molded-case Circuit Breaker
1Ry
1PL (Servo Alarm Display)
ALM+
ALM-
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay..
ProNet
Series Servodrives
1
2
B1
B2
B3
B2
B1
External Regenerator Resistor
B3
Ground Terminal
Three-phase 400V ProNet-10D50D
Noise Filter
L1 L2 L3
Three-phase 380~440V (50/60Hz)
+10%
-15%
Power OFF Power ON
1KM 1SUP
1KM
1Ry
L1
L2
L3
W
V
U
M
PG
Servomotor
Encoder
A(1)
B(2)
C(3)
D(4)
CN2
1Ry
1D
+24V
0V
Surge Protector
Magnetic Contactor
Molded-case Circuit Breaker
1Ry
1PL (Servo Alarm Display)
ALM+
ALM-
Be sure to connect a surge suppressor to the
excitation coil of the magnetic contactor and relay..
ProNet
Series Servodrives
1
2
B1
B2
B3
B2
B1
External Regenerator Resistor
B3
Ground Terminal
GND
24V
24VDC Power Supply

Table of Contents