ProNet Plus Series AC Servo User's Manual
The I/O signal connections diagram of the ProNet-□□□EG-EC servo drives is as shown in the following figure.
Allocable signals are as following:
S-ON: Servo ON
P-CON: P Control
P-OT: Forward Run Prohibited
N-OT: Reverse Run Prohibited
ALM-RST: Alarm Reset
ALM: Servo Alarm Output
Photocoupler Output:
Maximum Operating Voltage: DC30V
Maximum Output Current: DC50mA
TGON+11
COM2
14
S-RDY+
13
COM214
Allocable signals are as following:
COIN: Positioning Completion
TGON:Rotation Detection
S-RDY:Servo Ready
CLT:Torque Limit Detection
BK:Brake Interlock
PGC: Encoder C-Pulse Output
OT:Over Travel
RD: Servo Enabled Motor Excitation Output
HOME: Home Completion Output
ALM+
12
COM2
14
1Ry
1D
+24V
0V
+24V
DICOM
20
S-ON
15
P-CON
16
P-OT 17
N-OT
18
ALM-RST
19
3.3KΩ
Connect Shield to Connector Shell.
Shield
Shell
P
Represents Twisted-pair Wires
EXT1
3
EXT2
4
Signals EXT1 and EXT2 are unable
to allocate, which shall be
connected to external signals.
3.2.2 I/O Signal Names and Functions
Input Signals
The input signals description of ProNet-□□□MG servo drives is as shown in the following table.
Servo ON:Turns the servomotor on.
Function selected by parameter.
Proportional control
reference
Switches the speed control loop from PI
to P control when ON.
With the internally set speed
selection:Switch the rotation direction.
Enables control mode switching.
Speed control with zero-clamp
function:Reference speed is zero when
ON.
Position control with reference
pulse:Stops reference pulse input when
ON.
Forward run prohibited
Reverse run prohibited
Overtravel prohibited: Stops
servomotor when OFF.
Function selected by parameter.
Forward external
torque limit ON
Reverse external
torque limit ON
Current limit function enabled when
ON.
With the internally set speed selection:
Switches the internal speed settings.